1. VDI 2200 - leakage test & safety against blow-out – for flange connections

  • at temperature range from RT to 550°C
  • at pressure range 1bar
  • additionally at pressure 40bars (as addition to standard requirements)

2. VDI 2440 - leakage test TA-Luft for valves

  • at temperature range from RT to 550°C
  • at pressures range from 0 to 160bars
  • possibility of Live Loading apply during testing
     

Sample test run:

  • Assembly of the valve in the test rig
  • Preliminary test at RT: short term leakage test
  • Heating up to max. 400 °C
  • Stem cycles at test temperature (1,000 pcs.)
  • Tightness test 24 hours, test medium Helium, test pressure max 160 bar,
  • Disassembly after test
  • Evaluation of test results

3. VDI 2200 - blow-out test

  • test temperature acc. specification of manufacturer for the seal in mounted state
  • installation surface pressure as per Qmin/0,01 (EN 13555)